VERTICAL LABORATORY AUTOCLAVE (REGULAR MODEL)

APPLICATION

Years of experience have enabled SFE to contribute to improvement in all sterilization processes. Most widely used in sanitary and industrial fields to meet needs of pharmaceutical industry, laboratories research institutes and hospitals.

SFE Steam Sterilization Autoclaves find wide use in microbiological laboratories, research institutes, and ambulatory clinics and in all those applications in which high quality reduced overall dimensions are required.

Equipment’s Dimensions and Technical Features allow their installation inside the laboratory with no particular difficulties in positioning and connection.

TECHNICAL SPECIFICATION

MODELS

CAPACITY LITERS

INERTNAL SIZE  DIA. X HT CM

RATING (KW)

SFE05A

22

25X45

1.5

SFE05B

35

30X50

2

SFE05C

53

35X55

3

SFE05D

95

45X60

4

SFE05E

119

45X75

4.5

SFE05F

178

55X75

6

CONSTRUCTION -: Vertical double walled design, has single chamber for steam & water

  • Lid flange & bottom sheet also made of SS all joints Argon welded.
  • Joint less silicon Gasket. Heavy duty industrial flange heater.
  • Lid fitting Pressure gauge 0-30 PSI, Safety spring loaded Pressure valve, and Steam Release valve.

FEATURES -: Foot lifting arrangement is provided in ACL04 C/D/E/F Basket made of thick stainless steel (SS) rod wire mesh.

SAFETY-: Safety high Pressure release valve.

SUPPLY -: 230V AC Single Phase, 50 Hz.

STANDARD MODEL -: Inside SS 304 mirror finish & Outer SS 304 mirror finish.

TEMPERATURE RANGE -: 121° C TO 125° C

PRESSURE RANGE -: 15 to 22 PSI, factory set at 15 PSI.

SEMI AUTOMATIC SYSTEM FOR AUTOCLAVE

Supplied with Microprocessor Based Digital Temperature Controller with inbuilt Timer Low water level cut off system with magnetic float switch for heater’s safety.

FULLY AUTOMATIC SYSTEM FOR AUTOCLAVE

Supplied with Microprocessor Based Digital Temperature Controller With inbuilt Timer Automatic purging of steam with solenoid valve.

Low water level cut off system with magnetic float switch for heater’s safety.

FULLY AUTOMATIC SYSTEM FOR AUTOCLAVEwith printer interface

(To be order with fully automatic)

Supplied with Microprocessor Based Digital Temperature Controller with inbuilt Timer printer interface automatic purging of steam with solenoid valve.

Low water level cut off system with magnetic float switch for heater’s safety.

OPTIONAL

Safety pressure control switch

Vacuum breaker &self-purging system

4 channel self-data logger with printer interface

Safety Digital Temperature Controller

Water level indicator with glass tube

Foot pedal lifting arrangement for size no. A & B

Requirement for Installation

  1. Place the chamber where ventilation is good.
  2. The chamber must be operated in an ambient of 22◦ C ~ 30◦ C.
  3. Leave minimum 1ft. Space from the sides and leave 2ft. Space from the backside.
  4. Place the chamber horizontally levelled.
  5. Give stabilized electric supply (230V ±5%, 50Hz, 1 Phase, 20 Amp). It is recommended to use a voltage stabilizer (KVA).
  6. Proper grounding of the chamber to get satisfactory operation of chamber.
  7. Use of Soft water or D.M. water for humidity formation is recommended. Use of hard or salty water will damage the boiler heater.
  8. Do not test any product in the chamber, which is capable of generating combustible mixtures.