INDUSTRIAL HEAVY DUTY OVEN
APPLICATION
This ovens used for Roasting, drying, Pre-Heating or any other application where a dependable source of heated air up to 450˚C is required.
CONSTRUCTION
– Top to bottom vertical air flow
– G.I. or M.S. interior
– M.S. exterior with powder coated or painted
– All welded construction
– Explosion venting latches
– 2.5 kg per cu.feet. density G. W. Insulation
– Silicon rubber door gasket on up to 300 degree
– Adjustable fresh air & exhaust dampers
– High pressure recirculating blower
STANDARD FEATURES
SAFETY EQUIPMENT
– Adjustable, thermocouple actuated, manual reset
– Excess temperature controller
– Separate heating elements control contactors
– Re circulating blower air flow safety switch
STANDARD EQUIPMENT
Each features completely wired, top access control panel enclosing terminals for incoming power, temperature controllers, push buttons and poilet lights. Motor starter and heating element contactors electrically interlocked to shut off heaters if power to blower is interrupted and to permit operation of blower withoutheat for cooling. Incoloy sheathed tubular heating element on up to 450 degree. Exhaust outlet & fresh air is 4″x 4″ diameter dampers.
ADDITIONAL EQUIPMENT
- Programmable Temperature Controller, microprocessor based, digital indicating, and thermocouple actuated standard controller………………………….PTC1
- Recording Temperature Controller, thermocouple actuated, 24-hour, 10″ diameter circular chart used in conjunction with standard controller.RTC1
- Programmable Recording Temperature controller, microprocessor based, thermocouple actuated, digital display, 24- hour, 10″ diameter circular chart………………………………………………………………………………PRTC1
- Digital Timing System, incorporated into standard temperature controller, 99 hours 59 minute range, starts timing when temperature reaches set point and shut down oven at end of set time…………………………………………DTS
- Batch Timer, for uniformly timing batch operation, continuous alarm with door interlock, alarms at end of pre-set time period unit door is opened or timer reset. 1. 5, 10 or 30hr. range……………………………………………….BT
- Automatic Door switch turns off blower and heat when door is opened. Restores blower and heat when door is close…………………………..ADS
- Stainless steel, Interior and also exterior available……………………SS